<LOGO>
FM Transmitter Measurement Report
Created: 2025-07-06 10-33-53
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
96.90 MHz 4/5, 53 dBuV VOLTAGE
Pilot RDS Phase Difference
6.4 kHz 3.7 kHz -5 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
10 kHz 73 kHz 10018 50,4991
Modulation Power
Limit Measuring Tolerance
10,0 dBr 0,2 dBr
MIN AVE MAX % above 10,2 dBr
5,8 dBr 7,27 dBr 8,2 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"VOLTAGE " FE45 0 (No PTY) 1 0 0 2 10:33, 6.07.2025
RT
"VOLTAGE - Addictive Radio "
AF EON
96.9, 102.9 MHz -
FM Scope Station: 96.90 MHz, signal: 4/5 (54 dBuV) Max at: 73 kHz MIN: 10 kHz % above 75 kHz: 50,4991 Acquired: 2025/07/06 10:32:49 Total samples: 10018 Equivalent time: 0:08:20 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500
FM Scope MAX: 8,2 dBr MIN: 5,8 dBr AVE: 7,27 dBr % above 10,2 dBr: 0,0 Last value: 7,5 dBr (2025/07/06 10:32:49) Station: 96.90 MHz, signal: 4/5 (54 dBuV) 10:26 10:27 10:28 10:29 10:30 10:31 10:32 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality